Prince Manufacturing Corp.
Prince Flow Control Valves
Womack Machine Supply Company proudly partners with Prince Manufacturing Corp. to deliver the finest Mobile Pressure Control Valves available. Our collaboration ensures that customers in multiple locations across the United States have access to these exceptional products, click here to see available locations. Our commitment to excellence, combined with the reliability and performance of Prince Manufacturing Corp., guarantees that you receive top-quality Mobile Pressure Control Valves components for your specific needs.
FUNCTION The PRINCE model RD-500 is an adjustable constant volume priority divider. This valve provides the same function as the PRINCE model RD-400 except the priority flow is adjustable from 2 GPM to 12 GPM. The priority flow is set using the adjusting screw and is then locked in place to maintain setting. This allows setting to be fine tuned in the field to the exact flow needed. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
Item Number | Port Size | STOCKED ITEM |
RD-550 | 1/2" NPTF | |
RD-575 | 3/4" NPTF |
FUNCTION The PRINCE valve is a pressure compensated adjustable flow control valve. By rotating the handle, the flow out the "CF", or controlled flow port, can be varied from approximately 0 to the maximum controlled flow shown in the chart below. Any remaining flow is bypassed to the "EF" or excess flow port. This flow can be used to power another circuit or can be returned to tank. Once the controlled flow is set it will remain nearly constant with variations in pressure on either the controlled or excess flow ports. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 8 Ibs. |
Model No. | Port Sizes | Controlled Flow Range |
RD-150-8 | 1/2" NPTF | 0-8 GPM |
RD-150-16 | 1/2" NPTF | 0-16 GPM |
RD-175-30 | 3/4" NPTF | 0-30 GPM |
FUNCTION The PRINCE valve model RD-1400 is a double pilot-operated lock valve. This valve will lock a cylinder in place when a directional control valve is in the neutral position. In operation oil is directed to one of the valve ports and oil can free flow to the corresponding cylinder port. The pressure on this valve port will shift the pilot spool opening the opposite check valve. This will allow oil to return through the opposite check valve. This valve has a hardened steel seat and steel ball and therefore should not be used in applications requiring absolutely zero leakage. When using a pilot operated check to lower a heavy load the valve may chatter. An orifice in the line in some cases may be beneficial. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
Item Number | Port Size | STOCKED ITEM |
RD-1450 | 1/2" NPTF |
FUNCTION The PRINCE model RD-200 valve is a pressure compensated proportional flow divider. The standard models of this valve will take one inlet flow and split it into two nearly equal outlet flows. The valve is also available with special ratio spools which will split the flow into two flows proportional to the ratio specified. Because the valve is pressure compensated the valve will maintain the divider ratio with quite different loads on the outlet ports as long as the inlet flow is within the range given in the chart below. Flow through the RD-200 cannot be reversed. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
FUNCTION The PRINCE model RD-400 is a constant volume priority divider. It can be used in applications where two circuits are to be supplied by a single pump such as power steering systems. In operation the flow of oil supplied to the inlet is divided into two flows, the priority flow and the excess flow. The priority flow will remain nearly constant with variations in pressure on either the priority or excess flow port and will also remain nearly constant with variations in the inlet flow.The priority flow GPM is determined by a fixed orifice inside the main spool. The desired priority GPM must be specified with model number, see below. The PRINCE model RD-400R provides the same function as described above with the addition of a built in pressure relief for the priority port only. This relief is internally adjustable and requires a separate line to tank. The relief is factory set at 1,500 PSI. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
FUNCTION The PRINCE model RD-500P is a pressure compensated proportional flow divider valve with one fixed and one adjustable orifice. This valve will take one inlet flow and split it into two nearly equal outlet flows, the adjustable orifice allows the divider ratio to be changed in the field. Because the valve is pressure compensated the valve will maintain the divider ratio with quite different loads on the outlet ports as long as the inlet flow is within a given range. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
FUNCTION The PRINCE valve is a pressure compensated adjustable flow control valve. By rotating the handle, the flow out the "CF", or controlled flow port, can be varied from approximately 0 to the maximum controlled flow shown in the chart below. Any remaining flow is bypassed to the "EF" or excess flow port. This flow can be used to power another circuit or can be returned to tank. Once the controlled flow is set it will remain nearly constant with variations in pressure on either the controlled or excess flow ports. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 8 Ibs. |
Model No. | Port Sizes | Controlled Flow Range | |
RD-1950-16 | 1/2" NPTF | 0-16 GPM | |
RDRS-150-16 | 1/2" NPTF | 0-16 GPM | Built in relief set at 1500 PSI @ 10 GPM |
RDRS-175-16 | 3/4" NPTF | 0-16 GPM | Built in relief set at 1500 PSI @ 10 GPM |
RDRS-175-30 | 3/4" NPTF | 0-30 GPM | Built in relief set at 1500 PSI @ 10 GPM |
RDRS-1975-30 | 3/4" NPTF | 0-30 GPM | Built in relief set at 1500 PSI @ 10 GPM |
FUNCTION The PRINCE valve model RD-1000S is an internally piloted adjustable sequence valve. This valve will prevent the flow of oil from going to the sequence port until the pressure on the inlet port reaches the sequence pressure. The sequence pressure is adjustable within the range given in chart below. A built in check valve allows flow from sequence port to inlet. To operate properly the drain port must be connected to tank. This valve is a spool type sequence valve and will provide smooth operation but should not be used in applications that require low leakage. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
FUNCTION The PRINCE model RD-300 valve is a pressure compensated proportional flow divider. The standard models of this valve will take one inlet flow and split it into two nearly equal outlet flows. The valve is also available with special ratio spools which will split the flow into two flows proportional to the ratio specified. Because the valve is pressure compensated the valve will maintain the divider ratio with quite different loads on the outlet ports as long as the inlet flow is within the range given in the chart below. The valve free has reverse checks. This allows the reverse flow of oil from the outlet ports to the inlet port. The reverse flow is not pressure compensated. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 30 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 7 Ibs. |
Model No. | Divider Ratio | Port Size | Inlet Flow Range |
RD-350-16 | 50:50 | 1/2" NPTF | 8-16 GPM |
FUNCTION The PRINCE valve model RD-1600 is a pilot operated check valve. This valve blocks oil from flowing from the cylinder port to the valve port until sufficient pressure is applied to the pilot port. Oil can free flow from the valve port to the cylinder port. The valve has a two stage poppet allowing smooth chatter free operation. |
SPECIFICATIONS Pressure Rating Maximum Operating Pressure: 3,000 psi Flow Rating: 20 GPM Filtration: For general purpose valves, fluid cleanliness should meet the ISO 4406 19/17/14 level Maximum Operating Temperature: 180°F Weight: Approx 2 lbs. |
FEATURES:
|
Model No. | Port Size | Max PSI | Max Flow | Weight |
WFC-400 | 1/4" NPTF | 5000 | 5 GPM | .5 |
WFC-600 | 3/8" NPTF | 5000 | 8 GPM | .9 |
WFC-800 | 1/2" NPTF | 5000 | 15 GPM | 1.5 |
WFC-1200 | 3/4" NPTF | 5000 | 25 GPM | 2.5 |
WFC-1600 | 1" NPTF | 3000 | 40 GPM | 3.5 |
The PRINCE valve model W-1900 is a pressure compensated adjustable flow control valve. By rotating the handle, the flow out the “CF” or controlled flow port can be varied within the range given in the chart below. Any remaining flow is bypassed to the “EF” or excess flow port. This flow can be used to power another circuit or can be returned to tank. Once the controlled flow is set, it will remain nearly constant with variations in pressure on either the controlled or excess flow ports. Please note, if during operation the controlled flow port is blocked, the valve will compensate in such a way as to shut off flow to the excess port. This valve can also be used as a restrictive flow control by plugging the excess flow port. The PRINCE valve model WR-1900 has a built in adjustable pressure relief. For this model, the excess flow port must be connected to tank. It should be noted that whenever these or any valve is used to bypass or restrict flow, heat will be generated. Steps may be required to keep oil temperature from becoming too high. |
Model No. | Description |
W-1950-8 | ½-NPTF PORTS (0-8 GPM CF SPOOL) |
W-1908-8 | #8 SAE/ORB PORTS (O-8 GPM CF SPOOL) |
W-1950-16 | ½-NPTF PORTS (O-16 GPM CF SPOOL) |
W-1975-30 | ¾-NPTF PORTS (0-30-GPM CF SPOOL) |
W-1912-30 | #12 SAE/ORB PORTS (O-30 GPM CF SPOOL) |
WR-1950-16 | ½-NPTF PORTS (O-16 GPM W/RELIEF) |
WR-1975-30 | ¾ NPTF PORTS (0-30 GPM W/RELIEF) |
WR-1912-30 | #12 SAE/ORB PORTS (0-30 GPM W/RELIEF) |
AVAILABLE IN THESE LOCATIONS
- Alabama
- Arizona
- Arkansas
- Colorado
- Kansas
- Louisiana
- Mississippi
- Montana
- N.W. Florida
- Nevada
- New Mexico
- Oklahoma
- S. Idaho
- Texas
- Utah
- W. Missouri
- W. North Dakota
- W. South Dakota
- Wyoming
Contact Us For Pricing And Availability
If you’re interested in any of our products, or you have any questions about pricing and availability, let our team know today. We’re here to help!