OPERATION SCHEMATIC
RVP100 SERIES RESERVOIR, AIR OPERATED / DUAL REGULATORS ONLY

 

RESERVOIR CONNECTIONS
(See drawing to the right)

 

I 1/4 NPTF incoming shop air
II Regulated air to valve - 1/4 NPTF
III Regulated oil to valve - 1/8 NPTF
RESERVOIR FEATURES
1 Select capacity. 1 quart to 2 gallon (0.946 liter - 7.6 liter) polymer.
2 Filler cap.
3 Regulator - fluid pressure 30 PSIG (206.9 kPa) maximum.
4 Pressure gage - fluid.
5 Relief valve - set 30 PSI (206.9 kPa).
6 Regulator - air to spray valve.
7 Pressure gage - 0-30 PSI (0-206.9 kPa) to spray valve.
8 Filter - 40 micron.

 

 

SUGGESTIONS FOR SOLENOID OPERATION

CONTINUOUS SPRAY:

  • Wire both solenoids to auxiliary contacts on the "machine" being lubricated.
  • If over-run of liquid can be tolerated when the "machine" is shut down you can simplify the installation by omitting solenoids C and E and replacing the ball valve A with one solenoid valve P/N ESV512 wired to the auxiliary contacts.

TRIGGERED SPRAY with a rate less than 1O cycles per minute:

  • Wire both solenoids to an electromechanical switch or a non-contact switch which is activated by "machine" movement. Solenoid E for air should be installed as close as possible to the spray valve B.

PULSED OR TRIGGERED SPRAY with a rate more than 1O cycles per minute:

  • Wire solenoid C for liquid to a repeat cycle timer or "machine" activated trigger switch. Wire solenoid E for air to the "machine" auxiliary contacts so the air flows continuously to minimize droplet formation.

Do not use a filled fluid such as molydisulfide dispersion, teflon dispersion or any other particle dispersion. They will clog the fine openings of the unit, requiring a total dismantling of the system.

ITEM NOT INCLUDED WITH RESERVOIR
A 1/4 x 1/4 ball valve - shop air shut off.
B Spray Valve (P/N SV101, SV102 or SV103).
C Solenoid valve (P/N ESV501) - shut off oil to spray valve.
D 0.25 (6.35 mm) O.D. semi-rigid or metal as needed, and required fittings.
E Solenoid valve (P/N ESV501) - shut off air supply valve.